NOTE ** This section is based on preformed metal roof, wall, ceiling and soffit systems manufactured by ATAS International, Inc. Headquartered in Allentown, PA, ATAS also has a satellite manufacturing, service and warehouse facility in San Diego, California. ATAS produces many different types of preformed and prefinished enclosure systems in both aluminum and galvanized/Galvalume(R) steel for varied applications.
NOTE **
NOTE ** For more information or design assistance, contact ATAS as follows:
NOTE ** ATAS also has a catalog by Fax program, available on a 24-hour basis. Call 1-800-4-FAXCAT, follow the prompts, enter the code name for the product you are interested in, and ATAS will fax you pertinent data. FAXCAT Codes are indicated in the notes for each product.
NOTE **
NOTE ** SECTION 07410 - METAL ROOF AND WALL PANELS, Copyright 1997, The Architect's Catalog, Inc.
NOTE ** ATAS's capable staff is able to assist in the design or provide shop drawings for your project. Final choice of materials and installation is the responsibility of the owner, architect and/or the owner's agent. ATAS International, Inc. cannot be held responsible for the ultimate selection or the installation of those materials. Due to slight stresses created by a variety of conditions, from atmospheric to installation, the panel may have a wavy appearance (oilcanning) after installation. The greater the flat area of the panel, the greater the potential for slight imperfections to be noticed. This condition is beyond ATAS International's control, consequently, oilcanning or distortion of the product is not a valid reason for rejection of the materials. Should any manufacturing defects occur, ATAS International can only be held responsible for the replacement of materials. ATAS reserves the right to modify, eliminate and/or change its products without prior notification.
PART 1 GENERAL
1.1 SECTION INCLUDES
NOTE ** Delete items below not required for project.
A. Preformed aluminum roof panels.
B. Preformed steel roof panels.
C. Preformed aluminum wall panels.
D. Preformed steel wall panels.
E. Preformed aluminum ceiling and soffit system.
F. Flashings, fasteners, and accessories as required for weatherproof installation.
1.2 RELATED SECTIONS
NOTE ** Delete any sections below not relevant to this project; add others as required.
A. Section 05120 - Structural Steel: Building frame.
B. Section 05400 - Cold Formed Metal Framing: Exterior stud wall framing system.
C. Section 07220 - Roof Insulation.
D. Section 07260 - Vapor Retarders.
E. Section 07620 - Sheet Metal Flashing and Trim.
F. Section 07900 - Joint Sealers.
G. Section 08520 - Aluminum Windows.
H. Section 13121 - Pre-Engineered Buildings: Building framing system.
1.3 REFERENCES
NOTE ** Delete references from the list below that are not actually required by the text of the edited section.
A. AA DAF-45 - Designation System for Aluminum Finishes; The Aluminum Association, Inc.
B. AAMA 607.1 - Voluntary Guide Specification and Inspection Methods for Clear Anodic Finishes for Architectural Aluminum; American Architectural Manufacturers Association.
C. AAMA 608.1 - Voluntary Guide Specification and Inspection Methods for Electrolytically Deposited Color Anodic Finishes for Architectural Aluminum; American Architectural Manufacturers Association.
D. ASCE 7 - Minimum Design Loads for Buildings and Other Structures; American Society of Civil Engineers.
E. ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealled) by the Hot-Dip Process.
F. ASTM A 755/A 755M - Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil Coating Process for Exterior Exposed Building Products.
G. ASTM B 209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate.
H. ASTM B 370 - Standard Specification for Copper Sheet and Strip for Building Construction.
I. ASTM E 283 - Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen.
J. ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
K. ASTM E 1592 - Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference.
L. UL 580 - Standard for Tests for Uplift Resistance of Roof Assemblies.
1.4 PERFORMANCE REQUIREMENTS
A. Roof Panel System: Provide roof system with performance as specified when installed, designed in accordance with applicable codes.
B. Provide structural performance appropriate to substrate over which roof system is installed.
C. Wind Resistance:
NOTE ** Delete all but one of the following three definitions of design wind loads.
1. Design and size components to withstand loads caused by wind pressures as follows:
a. Positive pressure: ___ psf (___ kPa) normal to panel.
b. Negative pressure: __ psf (___ kPa) normal to panel.
2. Design and size components to withstand loads caused by wind pressures as specified in ASCE 7.
3. Design and size components to withstand loads caused by wind pressures as specified in applicable code.
4. Provide UL 90 rated system tested in accordance with UL 580.
5. Provide report of test conducted in accordance with ASTM E 1592, showing that panel system and anchorage to be used will withstand these design pressures.
6. Provide clip fastener pull-out test report and calculations.
NOTE ** Delete one of the following two paragraphs, describing deflection.
D. Maximum Deflection under Design Loads: 1/180 of span.
E. Maximum Deflection under Design Loads: 1/240 of span.
F. System Movement: Accommodate movements due to thermal expansion and contraction, dynamic loading, and deflection of structural support system without damage to panel system or loss of weatherproofing capability.
G. Air Infiltration: Maximum ____ cfm per square foot when system is tested in accordance with ASTM E 283 at a static pressure of ___ psf (___ kPa).
H. Water Penetration: No uncontrolled water leakage when system is tested in accordance with ASTM E 331 at static water pressure of ___ psf (___ kPa).
I. Drainage: Provide positive drainage to exterior for moisture entering building enclosure or condensation occurring within exterior building envelope.
1.5 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Manufacturer's Certifications:
1. Certified statement from panel manufacturer documenting manufacturer qualifications.
2. Certified statement from panel manufacturer that panels are tension-leveled during the roll-forming process.
C. Product Data: Manufacturer's current product specifications and installation instructions.
D. Shop Drawings: Include small scale roof plan and elevations, as required. Show details of trim and flashing conditions, fastening and anchorage methods, weatherproofing techniques, terminations, and penetrations.
E. Selection Samples: Submit actual metal chips with full range of colors available for Architect's selection.
F. Verification Samples: Submit two samples of each type of metal panel required, not less than 12 inches (305 mm), and illustrating finished panel profile, color, sheen, and texture.
G. Test Reports: Submit copies of test reports verifying:
1. Wind load performance of panels and anchors.
2. Air infiltration performance.
3. Water penetration performance.
4. Coating quality.
1.6 QUALITY ASSURANCE
A. Manufacturer Qualifications: Minimum of 10 years of experience in factory-fabrication and roll-forming of metal roof panels.
B. Installer Qualifications: Company specializing in the type of work required for this project, with not less than 2 years of documented experience.
C. Pre-Installation Meeting: Convene meeting not less than one week prior to beginning installation.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Comply with provisions of Section 01600.
B. Order materials based on field measurements, not on construction drawings.
C. Package panels at factory.
D. Coordinate delivery schedule with installation schedule. Do not deliver materials of this section to project site until suitable facilities for storage and protection are available.
E. Protect materials from damage during transit and at project site. Store under cover but sloped to provide positive drainage. Do not expose materials with strippable protective film to direct sunlight or extreme heat.
F. Do not allow storage of other materials or allow staging of other work on installed metal panel roof system.
1.8 WARRANTY
A. Comply with provisions of Section 01780.
NOTE ** Retain the following paragraph for Kynar 500(R)/Hylar 5000(R) fluoropolymer finish.
B. Submit manufacturer's standard 20 year finish warranty for color retention, adhesion, and freedom from chalking.
C. Submit 2 year weathertightness and workmanship warranty from installer.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Design is based on products manufactured by ATAS International, Inc., 6612 Snowdrift Road, Allentown, PA 18106. ASD. Tel: 610-395-8445.
B. Provide panels, anchor clips, closures, flashings, and accessories manufactured by a single manufacturer.
C. Substitutions: Comply with procedural requirements of Section 01600.
NOTE ** Delete the following sub-paragraphs if Section 01600 defines the limitations on and procedures for substitutions. Substitution requirements may also be specified in the Instructions to Bidders.
1. Requests for substitution of alternate systems must be made in writing at least 10 days prior to bid date.
2. Submit complete product and test data as specified under Submittals for each proposed substitution.
2.2 MATERIALS
A. Precoated Galvanized Steel Sheet: ASTM A 755/A 755M; ASTM A 653/A 653M, Structural Quality Grade 33/230, G90/ Coating Designation, precoated with Kynar 500(R)/Hylar 5000(R) finish.
B. Aluminum Sheet: ASTM B 209, minimum yield strength 17,000 psi (117 MPa). Prefinish as specified under panel type.
NOTE ** Delete any of the following aluminum finish descriptions that are not used on the project.
1. Clear Anodic Coating: AAM12C22A41 clear anodized coating complying with AAMA 607.1, 0.7 mil thickness minimum.
2. Color Anodic Coating: AAM12C22A44 coating electrolytically deposited and complying with AAMA 608.1, 0.7 mil thickness minimum.
C. Copper Sheet: ASTM B 370.
NOTE ** Delete finishes below not required by panel systems specified.
D. Fluoropolymer Coating: Provide multi-coat PVDF Kynar 500(R)/Hylar 5000(R) finish system on exposed metal surfaces.
E. Siliconized Polyester Coating: Manufacturer's standard coating system, factory-applied.
2.3 PANEL SYSTEMS
A. Roof Panel Systems: Provide factory-formed metal panel systems with continuous interlocking panel connections and all necessary components to ensure a weathertight installation, including but not limited to ridges, hips, valleys, eaves, rakes, corners, and miscellaneous flashing.
NOTE ** Select system desired and choose appropriate options under each panel type.
NOTE **
NOTE ** The Multi-Purpose Panels below successfully renovate industrial, commercial, and professional buildings and prove excellent for new construction as well. The 17 different profiles offered all present a sleek, smooth appearance, with a positive locking feature and no exposed fasteners. FAXCAT Code #1035
NOTE ** Note: The following profile is not available in either 0.040 inch aluminum or 24 gage steel; it is 3/8 inch in overall depth.
g. Profile: Vee Groove: MPS120.
6. Width: 16-inch (406 mm) panels.
a. Profile: Narrow Seam Batten: MPN160.
b. Profile: Wide Batten: MPW160.
c. Profile: 5 inch (127 mm) Board Batten: MPH165.
d. Profile: 7 inch (178 mm) Plank Batten: MPH167.
e. Profile: 5 inch (127 mm) Vee Batten: MPV165.
f. Profile: 7 inch (178 mm) Vee Batten: MPV167.
NOTE ** Delete one of the following two paragraphs: 1-1/4 inch depth applies to all types except MPS120; 1/2 inch applies to MPS120.
7. Panel Depth: 1-1/4 inches (32 mm).
8. Panel Depth: 1/2 inch (13 mm).
NOTE ** Panel lengths are cut to customer specifications and can range from 2 feet to any transportable length.
NOTE **
NOTE ** Note: For panel lengths over 25 feet, the Monarch Panel is recommended because of its clip installation system, which allows the panel to "float" for thermal expansion and contraction without distortion.
9. Panel Length: As indicated on drawings.
10. Panel Length: ___________________.
11. Texture: Smooth.
12. Texture: Stucco Embossed.
13. Finish: Kynar 500(R)/Hylar 5000(R).
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
14. Finish: Clear Anodized.
15. Finish: Bronze Anodized.
NOTE ** The Metafor wall panel is applicable to renovations and new construction and can be applied directly to wood or metal framing. The panel is 12 inches wide and has four ribs spaced 3 inches on center. Each rib is 1-1/2 inches wide by 5/8 inch deep, providing a consistent overall ribbed texture. FAXCAT Code #1035
C. Metafor Panel System (MFP120):
1. Material: 0.032 inch (0.81 mm) aluminum.
2. Material: 0.040 inch (1.0 mm) aluminum.
3. Material: 0.050 inch (1.29 mm) aluminum.
4. Panel Width: 12 inch (305 mm) coverage.
5. Panel Depth: 5/8 inch (16 mm).
NOTE ** Note: Panel length may vary from 2 feet to any transportable length.
6. Panel Length: As indicated on drawings.
7. Panel Length: _______________.
8. Texture: Smooth.
9. Texture: Stucco Embossed.
10. Finish: Kynar 500(R)/Hylar 5000(R).
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
11. Finish: Clear Anodized.
12. Finish: Bronze Anodized.
NOTE ** The Arc-Metafor system consists of standard Metafor panels that have been custom formed to either a concave or convex shape. Common applications are mansard profiles or curved fascias and soffits. FAXCAT Code #1036
D. Arc Metafor Panel System:
1. Profile: Concave: MFV120.
2. Profile: Convex: MFX120.
3. Material: 0.032 inch (0.81 mm) aluminum.
4. Panel Width: 12 inch (305 mm) coverage.
5. Panel Depth: 5/8 inch (16 mm).
NOTE ** Note: Minimum concave radius is 4 feet; minimum convex radius is 2 feet, 9 inches.
6. Panel Radius: As indicated on drawings.
7. Panel Radius: _______________.
8. Texture: Smooth.
9. Texture: Stucco Embossed.
10. Finish: Kynar 500(R)/Hylar 5000(R).
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
11. Finish: Clear Anodized.
12. Finish: Bronze Anodized.
NOTE ** The Opaline panel is a very practical system, offering profiles that look extruded but are more economically rollformed. Panels are installed in a basic tongue and groove system with mechanical fasteners that are hidden by subsequent panels. FAXCAT Code #1036
b. Profile: Flush with 1/2-inch (13 mm) Reveal: OPW045.
c. Profile: Curved with 1/2-inch (13 mm) Reveal: OPV045.
6. Width: 6 inch (150 mm) panels.
a. Profile: Flush: OPF060.
b. Profile: 1-inch (25 mm) Rib: OPN061.
7. Width: 6-1/2 inch (165 mm) panels.
a. Profile: Flush with 1/2-inch (13 mm) Reveal: OPW065.
8. Width: 8 inch (203 mm) panels.
a. Profile: Flush: OPF080.
b. Profile: 1-inch (25 mm) Rib: OPN081.
9. Width: 8-1/2 inch (216 mm) panels.
a. Profile: Flush with 1/2-inch (13 mm) Reveal: OPW085.
10. Panel Depth: 3/4 inch (13 mm).
11. Panel Length: As indicated on drawings.
12. Panel Length: ___________________.
13. Texture: Smooth.
14. Texture: Stucco Embossed.
15. Finish: Kynar 500(R)/Hylar 5000(R).
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
16. Finish: Clear Anodized.
17. Finish: Bronze Anodized.
NOTE ** The PC Systems are two piece systems, consisting of a pan and a snapped-on standing seam or batten. Battens are available in heights of 1 inch and 2 inches, and the standing seam is 1-1/4 inches tall. These systems are not structural and must be installed over solid underlayment. FAXCAT Code #1037
8. Cap Type: 1-1/4 inch (32 mm) standing seam: PCS114.
9. Cap Type: 1-inch (25 mm) high by 1-1/2 inch (38 mm) wide batten: PCB001; adds 1-1/4 inch (32 mm) to pan dimension for on center dimension.
10. Cap Type: 2-inch (50 mm) high by 1-1/2 inch (38 mm) wide batten: PCB002; adds 1-1/2 inch (38 mm) to pan dimension for on center dimension.
11. Panel Length: As indicated on drawings.
12. Panel Length: ___________________.
13. Texture: Smooth.
14. Texture: Stucco Embossed.
15. Finish: Kynar 500(R)/Hylar 5000(R).
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
16. Finish: Clear Anodized.
17. Finish: Bronze Anodized.
NOTE ** The Field-Lok Seam system is a standing seam system that requires field seaming equipment. Fastening is by means of clips concealed within the seams; either fixed or expansion type clips can be used, depending on project conditions. FAXCAT Code #1037
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
17. Finish: Clear Anodized.
18. Finish: Bronze Anodized.
NOTE ** Monarch Roof Panels are one-piece components with an integral seam that conceals the fasteners and clips used for installation. Available in 3 distinct profiles, Monarch panels have achieved UL 90 ratings for wind uplift. ASTM E 330 (modified) water and air infiltration tests have also been conducted. FAXCAT Code #1038
NOTE **
NOTE ** Note: MRC and MRD panels are not available in 0.050 inch aluminum. Availability of 22 gage steel and copper is subject to minimum quantities and adequate lead time.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
16. Finish: Clear Anodized.
17. Finish: Bronze Anodized.
NOTE ** ScanRoof is a metal "tile panel" that simulates the appearance of clay/concrete tile. An integral purlin gives structural integrity. Its light weight and high load bearing properties allow maximum spacing between trusses or reduction of roof truss dimensions, up to 4 feet on center, when compared to clay tile. FAXCAT Code #1040
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
NOTE ** The Techo Tile System is a vertical panel with a pattern that simulates Spanish tile. Panels are 5 "tiles" in width and 3 or more in height. FAXCAT Code #1040
NOTE ** Size of each "tile" on a Techo Tile panel is 8 inches in width and 14 inches in length. The panel can be produced to lengths that are multiples of the tile length, with a minimum of 3 tiles, or 42 inches. Stock length is 10 tiles high.
4. Panel Length: _________________.
5. Panel Depth: 2-1/8 inches (54 mm).
6. Pattern: Tile pattern, 0.576 inch (14.6 mm) step per tile.
7. Texture: Traditional (matte).
8. Texture: Glazed (smooth).
9. Finish: Kynar 500(R)/Hylar 5000(R).
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
NOTE ** Granutile is a metal panel in a tile configuration coated with colored stone granules and sealed with a clear polymer.
6. Finish: Stone granules coated with clear polymer.
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's 6 standard colors.
c. Color: ___________________.
NOTE ** Standing Seam Shingles give the appearance of the traditional standing seam, with the handling ease of 36 inch or 60 inch long panels. A four-way interlock insures weathertightness.
b. Color: As selected by Architect from manufacturer's 6 standard colors.
c. Color: ___________________.
NOTE ** Permashake panels simulate the look of wood grained shingles. The four-way interlocking panels are fastened with an anchor clip and lock system.
b. Color: As selected by Architect from manufacturer's 4 standard colors.
c. Color: ___________________.
NOTE ** CastleTop is a diamond shaped flat metal tile with an expanded polystyrene backer board. The backer gives strength to the panel, serves as an insulator, and aids in noise reduction. The turned down edge on the front and the turned up edge on the back give double sealing protection against the weather.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
NOTE ** The Belvedere system is a structural wall panel in three different styles, offering design freedom for all types of buildings. It can be installed either on a solid substrate or on spaced framing. FAXCAT Code #1036
O. Belvedere Wall Panel System:
1. Profile: Span Wall - BWS240.
a. Material: O.032 inch (0.81 mm) aluminum, embossed.
b. Material: 0.040 inch (1.0 mm) aluminum, smooth.
c. Material: 0.040 inch (1.0 mm) aluminum, embossed.
d. Material: 0.050 inch (1.29 mm) aluminum, smooth.
e. Material: 0.050 inch (1.29 mm) aluminum, embossed.
f. Material: 24 gage (0.61 mm) G90 galvanized steel, embossed.
g. Panel width: 24 inches (610 mm).
h. Panel depth: 4 inches (100 mm).
2. Profile: Box Panel - BWB360.
a. Material: 0.032 inch (0.81 mm) aluminum, embossed.
b. Material: 0.040 inch (1.0 mm) aluminum, smooth.
c. Material: 0.040 inch (1.0 mm) aluminum, embossed.
d. Material: 0.050 inch (1.29 mm) aluminum, smooth.
e. Material: 0.050 inch (1.29 mm) aluminum, embossed.
f. Panel width: 36 inches (915 mm).
g. Panel depth: 4 inches (100 mm).
3. Profile: Rib Panel - BWR360.
a. Material: 0.032 inch (0.81 mm) aluminum, smooth.
b. Material: 0.032 inch (0.81 mm) aluminum, embossed.
c. Material: 0.040 inch (1.0 mm) aluminum, smooth.
d. Material: 0.040 inch (1.0 mm) aluminum, embossed.
e. Material: 0.050 inch (1.29 mm) aluminum, smooth.
f. Material: 0.050 inch (1.29 mm) aluminum, embossed.
g. Material: 24 gage (0.61 mm) G90 galvanized steel, smooth.
h. Material: 24 gage (0.61 mm) G90 galvanized steel, embossed.
i. Material: 22 gage (1.0 mm) G90 galvanized steel, smooth.
j. Material: 22 gage (1.0 mm) G90 galvanized steel, embossed.
k. Panel width: 36 inches (915 mm).
l. Panel depth: 1-1/2 inches (38 mm).
NOTE ** Panel lengths for all Belvedere systems are cut to customer specifications, from 4 feet minimum (Span Wall 9 feet minimum) to 40 feet maximum.
4. Panel Length: _________________.
5. Finish: Kynar 500(R)/Hylar 5000(R).
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
NOTE ** The Design Wall system consists of a 12 inch wide panel in a choice of two distinct profiles - a smooth panel with stiffening ribs and a "board" panel. The "board" panel has an up side of 6 inches which may be extended in 1 inch increments. For every 1 inch increase in the width of the "board", the lower part of the panel increases equally, to give an overall coverage of up to 12 inches. FAXCAT Code #1036
8. Panel Profile: Board type, with adjacent recess and stiffening ribs.
9. Panel Profile: Board type, with adjacent recess and without stiffening ribs.
a. Panel depth: 1-3/4 inches (44 mm): DSH120.
b. Panel depth: 1 inch (25 mm): DWH120.
c. Board width: 6 inches (152 mm).
d. Board width: 7 inches (178 mm).
e. Board width: 8 inches (203 mm).
f. Board width: 9 inches (229 mm).
g. Board width: 10 inches (254 mm).
h. Board width: 11 inches (279 mm).
10. Panel Length: As indicated on drawings.
11. Panel Length: ___________________.
12. Texture: Smooth.
13. Texture: Stucco Embossed.
14. Finish: Kynar 500(R)/Hylar 5000(R).
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
NOTE ** The following is available only in 0.032 inch aluminum.
15. Lanced: Provide vented panels where indicated.
NOTE ** Linear Ceiling is available in two distinct profiles - round edge and a square box style panel, with or without filler strips. Each profile has a choice of three widths that are interchangeable due to the 4 inch module of the carrier system. FAXCAT Code #1039
Q. Linear Ceiling System:
1. Style: Round edge: LCR.
2. Style: Box edge: LCB.
3. Texture: Smooth.
4. Panel Width: 4 inch (100 mm) nominal.
5. Panel Width: 8 inch (203 mm) nominal.
6. Panel Width: 12 inch (305 mm) nominal.
7. Panel Depth: 5/8 inch (16 mm).
8. Material: 0.032 inch (0.81 mm) aluminum.
a. Finish: Kynar 500(R)/Hylar 5000(R).
b. Finish: Clear anodized.
c. Finish: Bronze anodized.
d. Color: As indicated on the drawings.
e. Color: As selected by Architect from manufacturer's standard colors.
f. Color: ___________________.
9. Material: 0.020 inch (0.51 mm) aluminum.
10. Material: 0.025 inch (0.64 mm) aluminum.
a. Finish: Siliconized polyester coating.
b. Color: As indicated on the drawings.
c. Color: As selected by Architect from manufacturer's standard colors.
d. Color: ___________________.
11. Closing Strip: Flush (with LCR Series only).
12. Closing Strip: Recessed.
NOTE ** The Wind-Lok(TM) panel system has been around for years and is still the best of its type. These panels can be used for wide overhangs and ceilings both indoors and out. The Wind-Lok(TM) installation method results in no exposed fasteners, and the panels are available in 6 standard colors. Unlike the tongue and groove method, the panels are hooked into each other, which prevents the panels from sagging in the middle, or slipping apart on wide ceilings. FAXCAT Code #1039
R. Wind-Lok(tm) Soffit Panel System:
1. Material: 0.019 inch (0.48 mm) aluminum, smooth.
2. Material: 0.024 inch (0.61 mm) aluminum, smooth.
3. Panel Style: Smooth: WLS120.
4. Panel Style: Vented: WLV120.
5. Panel Width: 12 inches (305 mm).
6. Panel Depth: 7/16 inch (11 mm).
7. Panel Length: ______________.
8. Finish: Siliconized polyester.
a. Color: As indicated on the drawings.
b. Color: As selected by Architect from manufacturer's standard colors.
c. Color: ___________________.
2.4 ACCESSORIES
A. Provide formed accessories of same gage and finish as the primary panel system, unless otherwise indicated on the drawings.
B. Anchor Clips: Concealed type, designed to allow for thermal movement of panels.
C. Sealants: As specified in Section 07900.
D. Fasteners: As recommended by manufacturer for project conditions and panel type.
2.5 FABRICATION
A. Panels: Factory-fabricate all panels with integral lock and seam design.
NOTE ** Delete the following paragraph if the panel type specified is not available in 70 foot lengths.
B. Fabricate panels up to 70 feet (21 m) long in one piece without transverse seams. Panels over 70 feet (21 m) long may be fabricated with seams; use manufacturer's standard end lap details.
C. Factory-fabricate trim and flashing components in minimum 12 foot (3.65 m) lengths, with allowance for thermal movement in joint design.
D. Form all components true to shape, accurate in size, square and free from distortion or defects. Cut panels to precise lengths indicated on approved shop drawings.
PART 3 EXECUTION
3.1 EXAMINATION
A. Inspect substrates to verify that they are in proper condition, spaced correctly, plumb, and are ready to receive panels and accessories.
1. Notify the Architect in writing if substrates are not suitable for application of panel system.
2. Do not proceed with installation until substrates are acceptable.
B. Verify actual dimensions in field prior to ordering materials.
3.2 INSTALLATION
A. Install metal panels and accessories in strict accordance with manufacturer's instructions and applicable codes.
B. Protect surfaces in contact with cementitious materials and dissimilar metals with bituminous paint.
C. Fasten panels to structural supports with concealed anchor clips, except where fixed attachment points are indicated. Install panels plumb, level, and true to line.
D. Fully interlock panels with adjacent panels; apply sealants as recommended by panel manufacturer to achieve weathertight installation.
NOTE ** Delete paragraph below if no roof panels are required for project, or if ScanRoof or Techo Tile roofing systems are specified.
E. Install roof panels with no transverse seams.
F. Do not allow shavings, metal dust, or chips to fall on panels.
3.3 ADJUSTING AND CLEANING
A. Remove all protective masking from material immediately after installation.
B. Touch up minor abrasions with matching paint provided by panel manufacturer. Remove and replace panels that cannot be satisfactorily touched up.
C. Sweep and remove chips, shavings, and dust from roof on a daily basis during installation period. Leave installed work clean, free from grease, finger marks and stains.
D. Upon completion of installation, remove scraps and debris from project site.
3.4 PROTECTION
A. Provide protection as required to assure that completed work of this section will be without damage or deterioration at date of substantial completion.